This handheld oscilloscope with multiple functions is really practical and professional. It has the functions of a multimeter which can measure voltage, current, capacitance, etc. Its sampling rate is 1GSa/s and its bandwidth is 60MHz-200MHz. 1M Memory Depth, and 6000 Counts DMM with analog bargraph; 5.6 inch TFT Color LCD Display, High Resolution(640*480).

Features:
High Bandwidth 200/100/60MHz Oscilloscope, 1GS/s sample rate, and 6000 Counts DMM with analog bargraph.
1M Memory Depth.
High Refresh Rate (2500 frames).
Large 5.6 inch TFT Color LCD Display; High Resolution(640*480); Dual-Window Design --More clear, More Detailed.
One-touch automatic setup optimizes the position, range, timebase, and triggering to assure a stable display of virtually any waveform.
Easy-to-use pop-up menu with built-in multi-language help system.
32 Automatic Measurements.
Waveform Math: Add, Subtract, Multiply, and Divide.
Store and recall over.
Automatic cursor tracking measurements.
XY Mode.
Built-in FFT function converts a time-domain signal into its frequency components to measure harmonic content and distortion in systems.
Waveform Recorder to capture/replay input waveforms from CH1 and CH2 with a maximum record length of 1000 frames.
Pass/Fail function compares a stored waveform to an unknown input.
Average Mode for smoothing waveforms.
Square Wave Output (2V, 1kHz) for probe adjustment.
USB Host/Device 2.0 full-speed interface; support removable disk; LAN Option, easy to control by PC or long-distance.
Dimensions (mm): 245(L)x180(W)x55(H), be carried easily.

Specifications:
Brand: Hantek
Model: DSO1202B / DSO1102B / DSO1062B (Optional)
Channel: 2 Channels
Bandwidth: 200MHz / 100MHz / 60MHz (Optional Model Corresponded)
Sampling Rate: 1GSa/s
Equivalent Sample Rate: 25GSa/s
Power Adapter: 100-240V 50/60Hz
Plug Type: AU / US / EU (All Included)
Battery: 1 * 727076 Lithium Battery
Current: 4500mAH
Voltage: 7.4V
Material: ABS
Oscilloscope Probe Model: PP-200B 200MHz / PP-150B 100MHz / PP-80B 60MHz (Optional Model Corresponded)
Item Size: Approx. 24.5 * 18 * 5.5cm / 9.6 * 7.1 * 2.2in
Item Weight: 
DSO1202B: Approx. 1182.9g / 41.7oz
DSO1102B: Approx. 1197.8g / 42.2oz
DSO1062B: Approx. 1189.2g / 41.9oz
Package Size: Approx. 32 * 12 * 30cm / 12.6 * 4.7 * 11.8in
Package Weight:
DSO1202B: Approx. 2.33kg / 5.15b (2334.3g / 82.3oz)
DSO1102B: Approx. 2.35kg / 5.19b (2352.5g / 83.0oz)
DSO1062B: Approx. 2.35kg / 5.17b (2347.3g / 82.8oz)

Hardware Specifications:
ModelDSO1202BDSO1102BDSO1062B
Acquisition
Sample ModesReal-Time Sample: 1GS/s;
Equivalent Sample: 25GS/s
Acquisition Modes
NormalNormal data only
Peak DetectHigh-frequency and randon glith capture
AverageWavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs CouplingAC, DC, GND
Inpits Impendance1MΩ±2% ‖20pF±3pF
Probe Attenuation1X, 10X
Supported Probe Attenuation Factor1X, 10X, 100X, 1000X
Maximum Input VoltageCAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range500MS/s--1GS/s
Waveform Interpolation(sin x)/x
Record Length1M
SEC/DIV Range2ns/div~2000s/div,4ns/div~2000s/div,
Sample Rate and
Delay Time Accuracy
500ps(at over any ≥1ms time interval)
Position Range2ns/div to10ns/div;
(-4div×s/div) to 20ms;
4ns/div to 8ns/div; (-8div x s/div) to 40ms;
20ns/div to 80μs /div;(-8div×s/div)to 40ms;
200μs/div to 40s/div; (-8div×s/div)to 400s;
Delta Time Measurement Accuracy
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical
Vertical Resolution8-bit resolution, all channel sampled simultaneously
Position Range2mV/div to 200mV/div, ±2V
200mV/div to 5V/div, ±50V
Bandwidth200MHz100MHz60MHz
Rise Time at BNC( typical)1.8ns3.5ns5.8ns
Analog Bandwidth in
Normal and Average
modes at BNC or with probe, DC Coupled
2mV/div to 20mV/div, ±400mV;
50mV/div to 200mV/div, ±2V;
500mV/div to 2V/div, ±40V;
5V/div, ±50V
Math+, -, *, /, FFT
FFTWindows: Hanning、Flatop、Rectamgular、Bartlett、Blackman; 1024 sample point
Bandwidth Limit20MHz
Low Frequency Response (-3db)≤10Hz at BNC
DC Gain Accuracy±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability,
Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger
Trigger TypesEdge, Video, Pulse, Slope, Over time, Alternative
Trigger SourceCH1, CH2, AC Line
Trigger ModesAuto, Normal
Coupling TypeDC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
AC: Attenuates signals below 10Hz ;
HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level RangeCH1/CH2: ±8 divisions from center of screen;
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20nsCH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
Set Level to 50%(typical)Operates with input signals ≥50Hz
Video Trigger
Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions;
Signal Formats and Field Rates, Video Trigger TypeSupports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger PointEqual: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range20ns ~ 10s
Slope Trigger
Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range20ns ~ 10s
Overtime Trigger
Over Time ModeeRising edge or Falling edge
Time Range20ns ~ 10s
Alternative Trigger
Trigger on CH1Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution6 digits
Accuracy (typical)±30ppm (including all frequency reference errors and ±1 count errors)
Frequency RangeAC coupled, from 4Hz minimum to rated bandwidth
Signal SourcePulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor MeasurementVoltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT)
Auto MeasuermentFrequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,
General Features
Display
Display Resolution640 horizontal by 480 vertical pixels
Display ContrastAdjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical)About 5Vpp into ≥1MΩ load
Frequency(typical)1kHz
Power Supply
Supply VoltageAC Input:100-240VACRMS,0.6A MAX,50Hz~60Hz; DC Output:9V,2A
Power Consumption<30W
Environmental
TemperatureOperating: 32℉ to 122℉ (0℃ to 50℃);
Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
Cooling MethodConvection
Humidity+104℉ or below (+40℃ or below): ≤90% relative humidity;
106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
AltitudeOperating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)
Mechanical
SizeLength 245mm; Width 180mm; Height 55mm
Weight2.4KG(with Packing); 1.2KG(without Packing)
DMM Mode
Max. Resolution6000 Counts
DMM Testing ModesVoltage, Current, Resistance, Capacitance, Diode & Continuity
Max. Input VoltageAC:600V, DC: 800V
Max. Input CurrentAC: 10A, DC:10A
Input Impedance10MΩ
DMM TrendPlot1.2M Point
RangeResolutionAccuracyResolution
DC Voltage60.00mV±1%±3 digit10uV
600.0mV100uV
6.000V1mV
60.00V10mV
600.0V100mV
800V1V
AC Voltage60.00mV±1%±3 digit10uV
600.0mV100uV
6.000V1mV
60.00V10mV
600.0V100mV
DC Current60.00mA±1%±5 digit10uA
600.0mA±1.5%±5 digit100uA
6.000A1mA
10.00A10mA
AC Current60.00mA±1%±5 digit10uA
600.0mA±1.5%±5 digit100uA
6.000A1mA
10.00A10mA
Resistance600Ω±1%±3 digit0.1Ω
6.000KΩ
60.00KΩ10Ω
600.0KΩ1KΩ
6.000MΩ10KΩ
60.00MΩ±1%±5 digit100KΩ
Capacitance40.00nF±2%±5 digit10pF
400.0nF100pF
4.000uF1nF
40.00uF10nF
400.0uF100nF
Attention: the smallest capacitance value that can be measured in 5nF
Diode0V~2.0V
ON-OFF test<10Ω

Note:
Hantek DSO1202B/DSO1102B/DSO1062B Oscilloscope is for 3 years Warranty!
Please read the instruction manual data CD carefully to avoid injury and prevent damage to this product.

Package List:
1 * Portable Oscilloscope
1 * Oscilloscope Tool Bag
2 * Oscilloscope Probes
2 * Test Lead Probe for Multimeter 
1 * Power Adapter
3 * Plug
1 * USB Cable
1 * Bag Strap
1 * Upper Computer Software CD
1 * User Manual