*Size: Height 1420mm, Arm length 950mm (Longest) tripod width700mm
*Input power: AC110 or 240V,5060 Hz
*Output power: 24V (8 imported LED bulbs, cold light intensity is not general)
*Power: 30W
* Host Operation Instructions
1: Plug the whitening power plug into the applicable power socket, open the power supply box power switch. The host's display will light up and display the parameters before the last shutdown.
2: Press the Time key to display the time will be flashing, at this point can be (▲) under () Key adjustment time, each press will increase or decrease 1 minutes, the maximum adjustment time is 30 minutes, according to the need to set whitening time, set up and then press Time key to determine the time set.
3: Press power key, output power value will flicker, at this point can be adjusted on (▲) under () key to set the desired value, each press can be increased or reduced by 10%, the power output range from 40 full power output optional, according to the need to customize the set after the completion of the power key to determine the selected power.
4: Press the A/b group key, pipe group selection will be flashing, at this time through the (▲) key to determine their desired output requirements, the output status of 3 kinds: A: A separate group A output, B: A separate B-group output; After selecting the desired output status, press A/b key to confirm.
5: Press Start/stop key, the output of the tube will be lit, at this time the United States whitening will follow the set requirements to work, the display will show the rest of the work, if the time has come to the United States whitening will automatically shutdown;
Note: After the US whitening stop the output, the internal cooling fan will work for 1 minutes to protect the LED tube and the safety of the system.
6: The United States whitening inside also has a temperature protection device, when the blue led tube temperature of more than 60 Shan, the United States whitening will automatically stop working to protect the safety of the department.
* Warning and Precautions:
1: Strictly prohibit the whitening output of blue light to the eyes of people, otherwise the eyes will be seriously hurt, whitening instrument work, patients and doctors must wear protective glasses to prevent blue light damage eyes.
2: Adjust the host position, need a hand-held host, another hand stick, and then slowly pull the bracket to adjust the host in the appropriate position to prevent the United States whitening turned, but also to avoid the movement of feet.
3: Whitening before the United States whitening disinfection.
4: Each time the use is completed, should turn off the power supply in time, is strictly prohibited to have the hard thing collision or the liquid kind of thing contact us whitening.
* Whitening Treatment Instructions
1: Put the wet cotton strips into the guest's lip, apply Vaseline in the lip and sticky place to prevent the whitening agent from accidentally dripping, causing damage to the lip; wear goggles.
2: With a three-gun blow dry gum and the surface of the teeth of the water, gum protection resin loaded with needles evenly injected at the gum edge, and covered with the next 0.5mm. Until the gingival sulcus is completely closed, use the oral endoscopy to ensure that the gingival sulcus can not be seen.
3: The whitening whitening irradiation all the coating area about 30 seconds until the gum protection resin color fades and hardens.
4: The hydrogen peroxide and the United States into a gel-like (note: The more hydrogen peroxide to join the better.) The United States powder agent in addition to excessive liquid lead to colloid too dilute, stir with stirring a few times will automatically thicken, so as to ensure that whitening agent to absorb hydrogen peroxide maximum, the final consistency to use the brush to stir the whitening agent does not drip as the quasi), will be adjusted to apply the colloid on the upper and lower 8 or more of the tooth surface, smear thickness about 2-3mm; (Note: The whitening agent is strictly prohibited from contacting any part of the tooth to prevent injury).
5: Adjust the whitening lamp holder, the lamp holder should be 90 degrees perpendicular to the surface of the tooth, and maintain the appropriate distance with the aperture (about 5cm) so that the spot can converge into the size of the tooth fit, press the Start button, start the first 10-15-minute session, the course of the machine will show the rest of the time, (if 8 minutes after the guests reflect the sensitive teeth or pain is very strong, should stop whitening operation and use desensitization agent to clean the surface of the tooth). Suggestion: The general operation time is 15 minutes (if have allergy, ache and so on adverse reaction, can illuminate 10 minutes each time, in order to achieve the better whitening effect.
6: The first 10-15 minutes after the end of whitening, the machine automatically stop irradiation, remove the treatment of bald head, with a suction thoroughly remove whitening material (do not wash water)
7: Repeat step 7-9 for the second and third time whitening; The guest has a deep tooth stain and can be added a whitening after two weeks.
*package:1* Teeth Whitening Machine