Product Parameter:
1. Display: LCD, 1999 counts updates 2/sec
2. LCD size: about 40 x 20 mm/ 1.57 * 0.79 inches
3. Polarity Indication : - displayed automatically
4. Over-range Indication: OL displayed
5. Low Battery Indication: displayed
6. Range select: auto or manual
7. Operation Temperature: 0°C to 40°C, less than 80%RH
8. Storage Temperature: -10°C to 50°C, less than 85%RH
9. Battery Type : 3V x 2,2032 size
10. Dimension(H×W×D): about 110 × 55 × 10 mm/ 4.33 * 2.17 * 0.39 inches
11. Weight: about 100 g
12. DC VOLTAGE (Auto ranging)
Range Resolution Accuracy
200mV 0.1mV ±(0.8% of rdg + 5dgts)
2V 1mV ±(0.5% of rdg + 2dgts)
20V 10mV
200V 100mV
600V 1V ±(1.0% of rdg + 5dgts)
Input Impedance: 10 M
Overload Protection: 600V DC/AC rms
Maximum Input voltage: 600V DC
13. DC CURRENT
Range Resolution Accuracy
200µA 0.1µA ±(0.8% of rdg + 5dgts)
2000µA 1µA
20mA 10µA
200mA 100µA
Overload Protection: F0.5A/600V fuse
Maximum Input Current: 500mA
Voltage Drop: 1) 200µA and 20mA; Ranges: 20mV
2) 2000µA and 200mA; Ranges: 200mV
14. AC CURRENT
Range Resolution Accuracy
200µA 0.1µA ±(1.0% of rdg + 5dgts)
2000µA 1µA
20mA 10µA
200mA 100µA
Overload Protection: F0.5A/600V fuse
Maximum Input Current: 500mA
Voltage Drop: 1) 200µA and 20mA; Ranges: 20mV
2) 2000µA and 200mA; Ranges: 200mV
Frequency Range: 40Hz ~ 400Hz
Response: Average, calibrated in rms of sine wave
15. AC VOLTAGE (Auto ranging)
Range Resolution Accuracy
2V 1mV ±(1.2% of rdg + 3dgts)
20V 10mV
200V 100mV
600V 1V ±(1.2% of rdg + 8dgts)
Input Impedance: 10M
Frequency Range: 40Hz ~ 400Hz
Overload Protection: 600V DC/AC rms
Response: Average, calibrated in rms of sine wave
Maximum Input voltage: 600V AC rms