This multimeter with stable high performance, high accuracy and accurate measurement is highly reliable. It can be used to measure DC voltage, AV voltage sine wave TRMS, DC current, AC current sine wave TRMS, resistance, diode, capacitance, temperature, frequency, duty circle, triode(HFE) and continuity. Most suitable for use on production lines or for lab, R & D, family,maintenance and repair work.
Features:
The multimeter can be used to measure voltage, current, inductance, resistance, diode, temperature, capacitance, frequency, duty circle, triode(HFE) and continuity.
Great instrument for use in production lines or for lab, R & D, family,maintenance and repair work.
With data hold and auto power off function, convenient to use.
Dual slope A-D Converter uses C-MOS technology.
LCD display with white manual backlight.
It also has non-contact voltage detection, data hold function.
Continuity test with LED indication and buzzer indication.
Powered by a 9V battery(not included), low consumption.
Low battery indication and manual range.
Specifications:
Brand Name: UYIGAO
Color: Grey + Orange
Material: ABS
Maximum Display: 3 5/6 LCD
Technical Index:
1.DC voltage?DCV?
| range | accuracy | Resolution |
| 600mV | ±(0.5%+5d) | 0.1mV |
| 6V | 1mV | |
| 60V | 10mV | |
| 600V | 100mV | |
| 1000V | ±(1.0%+6d) | 1V |
Input impedance:600mV>60M맺,10M맺
Overload protection? a)mV range DC current or 250V AC peak
b)1000V DC current or 750V AC peak
2. AC voltage
| range | accuracy | Resolution |
| 6V | ±(1.2%+5d) | 1mV |
| 60V | 10mV | |
| 600V | 100mV | |
| 750V | ±(1.5%+5d) | 1V |
Input impedance? 10M맺
Overload protection:a)mV range DC current or 250V AC peak
b)1000V DC current or 750V AC peak
Frequency response: 40 ~ 1000
Display: the average response (the effective value of sine wave calibration)
Duty display: (0.1%-99.9%)
3.DC current?DCA?
| range | accuracy | Resolution |
| 60uA | ±(0.8%+10d) | 0.01鈴A |
| 6mA | 1鈴A | |
| 60mA | 10鈴A | |
| 600mA | ±(1.2%+10d) | 100鈴A |
| 10A | ±(2.0%+10d) | 10mA |
Maximum input current?10A?No more than 15 seconds?
Overload protection?0.4A/250V recovery fuse
10A/500V fuse
4.AC current?ACA?
| range | accuracy | Resolution |
| 6mA | ±(1.0%+10d) | 1.0鈴A |
| 60mA | 10鈴A | |
| 600mA | ±(1.5%+10d) | 100鈴A |
| 10A | ±(2.5%+10d) | 10mA |
Maximum input current: 10 A(not more than 15 seconds).
Overload protection: 0.4 A / 250 recovery fuse;10A/500V fuse
Frequency response: 40 ~ 1000 Hz
Duty ratio : (0.1% ~99.9%)
5. Resistance?맺?
| range | accuracy | Resolution |
| 600맺 | ±(0.8%+10d) | 0.1맺 |
| 6k맺 | ±(0.8%+3d) | 1맺 |
| 60k맺 | 10맺 | |
| 600k맺 | 100맺 | |
| 6M맺 | 1k맺 | |
| 600M맺 | ±(1.2%+10d) | 100k맺 |
open-circuit voltage?about 1.0V?
Overload protection?250V DC current or AC current peak value
6. Diode and continuity Test
| range | value | test conditions |
|
| Positive voltage | Positive DC current about1.0mA? |
|
| About 50맺 | open-circuit voltage 1.0V |
Overload protection?250V DC current or AC current peak value
warning?For the sake of safety,donot input voltage range.
7. Capacitance
| range | accuracy | Resolution |
| 10nF | ±(4.0%+10d) | 0.001nF |
| 100nF | ±(3.0%+5d) | 0.01nF |
| 1鈴F | 0.1nF | |
| 10鈴F | 10nF | |
| 100鈴F | 10nF | |
| 6000鈴F | ±(5.0%+10d) | 100nF |
Overload protection?250V DC current or AC current peak value
Note?Below 100PF maybe cannot test
8.Frequency ?Hz%?
| range | accuracy | Resolution |
| 100Hz | ±(0.5%+3d) | 0.1Hz |
| 1000Hz | 1Hz | |
| 10kHz | 10Hz | |
| 100kHz | 100Hz | |
| 1MHz | 1kHz | |
| 10MHz | 10kHz |
sensitivity?2.0V
Overload protection? 250V DC current or AC current peak value
Duty ratio? (0.1%-99.9%)
range | accuracy | Resolution |
| 0.1%-99.9% | ±(0.5%+3d) | 0.1% |
9.Triode
| range | Display range | Test condition |
| HFE(NPN or PNP) | 0-1000 | Base current about 1mA VCE |
10.Temperature
| range | accuracy | Resolution |
| 0〕?300〕 | ±(1.0%+4d) | 1〕 |
| 301〕?1000〕 | ±(1.9%+5d) | 1〕 |
| 32팥?600팥 | ±(1.2%+6d) | 1팥 |
| 601팥?1832팥 | ±(1.9%+6d) | 1팥 |
Thermocouple? Kthermocouple
10. NCV
Set the function to NCV range and the meter display“EF” symbol. Put the meter close to the test object,when the object’s voltage is more than 110V(AC RMS) and the meter display “?”symbol,When sensing voltage is higher and shows more “?”symbol,the buzzer alarm sound the more densely populated.The red l ight is more bright.