Click here to Enlarge
Click to Enlarge
 
Click here to Enlarge
Click to Enlarge
 

 

Description:

HP350 is a RF power meter, based on continuous compression technology fully monolithic 500 MHz demodulating logarithmic amplifier , the logarithmic amplifier provides 92 dB dynamic range, even at frequencies up to 100 MHz can still provide error is ± l dB dynamic range of 88 dB.

The meter button to complete the operation, advantages: simple structure, easy to use, stable performance, reliable, high sensitivity and measurement speed and so on.

Application:

RF power measurement;

Meter calibration

Technical Data Sheet:

Measuring power range: -80 ~ +10 dBm (external RF attenuator can be extended to 100dBm)

Measuring Power Resolution: 0.1 dBm

Measurement frequency range: 1 ~ 500 MHz

Measuring power: 1nW ~ 2W

Voltage: 7 ~ 12 VDC

Working current: <50 mA

Working temperature: -40 °C ~ 65 °C

Storage temperature: -40 °C ~ 65 °C

Size: 55mm * 45mm * 10 mm

Interface display and operating instructions:

Unit Description: dBm;

Key Description:

FUN: function keys; MODE: set changer interface; SEL: Self plus key or self minus key ;

Display measurement data

Interface display font:

The first line "RF-POW -80.3 dBm"

The second line "20uV 0nW"

Note: the dBm value signal are shown, input voltage, the input power.

Set the RF power attenuation values

Interface display font:

The first line "RF Attenuator"

The second line "SUB 000dB"

Key operation:

FUN: function keys; (select plus or minus direction) as shown SUB Subtract, shows ADD a plus. (Long press FUN key to save the setting values in dB)

SEL: Self plus key or minus key to Self;

Note: External different RF power attenuator, set the corresponding attenuation coefficient reads the correct power parameters.

Wiring:

P1 connection definition:

VDD :power supply positive (7V ~ 12V)

GND: power supply negative

P2 connection definition:

FX :Unused

RF:RF signal input

GND: electronic scales power supply negative

 

 

';