Introduction
XMT Series Intelligent Temperature Controller adopts SCM for core which Micro anti-interference, large-capacity and advanced PID self-tuning method, and advance SMT technic, and the red/green double rows display measurement-value and setting-value at the same time.use advance components with software,
multipledigital filter technology,stable performance, higher measurement accuracy and strong
anti-interference. Various kinds of parameters can be set in the panel, it can realize various classic or modern controlling technology like two digis, three digits, intelligent PID, and parameter auto-optimization& auto-adjusting according to different require, and is mainly uses in self-control system like machines,chemical,ceramic,light industry,metallurgy petrifaction, petrochemical and heat treatment.
Notice
--Thermal resistance or thermocoupleinput and measuring range both can be set freely.
--Softwareadjust zero and full scale, temperature measuring of cold-end alone, amplifier constant-zero, display accuracy is better than 0.2%FS.
--The method of fuzzy theory combine with the traditional PID makes the temperature be controlled quickly and smoothly.
--The method of advanced PID parameter self-tuning saves a third time as compared with ordinary instrument.
--The output signal is optional: relay output, DC12V driver solid state relay, 4-20mA current
--Alarm output: two circuit user-defined alarm output.
Model | XMTE-2581 |
Max Load Current | 60mA |
Input Specifications | K.(J).E.Pt100(set freely) |
Output Signal | DC12V Voltage output |
Temp Control Range | (0-400℃ default)K(0-1350℃) ,J(0-1000℃) ,E(0-1000℃),Pt100(-200-650℃) |
Precision | 0.5 class(±0.5%F+1) |
Sampling Rate | Twice per second |
Regulating Methods | Intelligent PID control, according to the value of P,I,D parameters, we can get P(P=0 is on-off control),PI,PD,PID regulating mode |
Alarm function (optional) | One upper limit Alarm Alarm acts when at deviation of 10 (changable) |
Power supply | Transformer AC220V±10% |
Power Consumption | ≤3VA |
Contact Capacity | AC250V 2A (Resistive Load) |
Contact Life | >10x104 times |
Main Usage | Controlling temperature of ON/OFF in SSR SSR-DA,SSR3-DA |
General Information | |
Ambient temperature | -10-50℃ |
Relative humidity: | ≤85%RH(non-corrosive) |