| General specifications: | ||
| Safety Standards: | IEC1010-1, CAT. III 600V & CAT. II 1000V | |
| Pollution degree: | 2 | |
| Operating temperature: | 0~40 Celsius Degree, 32~122 Fahrenheit (<80%RH, <10 Celsius Degree non-condensing) | |
| Storage temperature: | -10~60 Celsius Degree, 14~140 Fahrenheit (<70% RH, battery removed) | |
| MAX. V between terminals & earth: | 750V AC rms or 1000V DC. | |
| Fuse protection: | uA / mA: Resettable fuse (400mA/250V); 10A: F 10A/250V (length * diameter: 6.3 * 32 mm) | |
| Display: | 3 3/4 digits LCD display | |
| Max. displayed value: | 3999 digits | |
| Over range indication: | LCD will display "OL". | |
| Sample rate: | 3 times/sec for digital data | |
| Auto power off time: | 15 min | |
| Power supply: | 3 * 1.5V AAA battery (not included) | |
| Multimeter size: | 19.5 * 9.2 * 5.5cm / 7.7 * 3.6 * 2.2in | |
| Multimeter weight: | 376g / 13.28oz | |
| Package size: | 24 * 17 * 6.5cm / 9.4 * 6.7 * 2.6in | |
| Package weight: | 545g / 19.22oz | |
| Measurement specifications (accuracy): | ||
| DC Voltage | 400mV/4V/40V/400V | ±0.7% |
| 1000V | ±0.8% | |
| AC Voltage | 400mV | ±3.0% |
| 4V/40V/400V | ±0.8% | |
| 750V | ±1.0% | |
| Resistance | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ | ±1.2% |
| 40MΩ | ±2.0% | |
| Capacitance | 4nF | ±5.0% |
| 40nF/400nF/4uF/40uF/200uF | ±3.0% | |
| Frequency | 9.999Hz/99.99Hz/999.9Hz/9.999kHz/99.99kHz/199.9kHz | ±2.0% |
| >200kHz | Unspecified @ >200kHz | |
| DC current | 400uA/4000uA/40mA/400mA | ±1.2% |
| 10A | ±2.0% | |
| AC current | 400uA/4000uA/40mA/400mA | ±1.5% |
| 10A | ±3.0% | |