DLMC Home Life? Blowing Alcohol Tester / Breath Alcohol Testing Equipment for Household-Type
Product Features:
1 thousandth digit display alcohol tester
2 three unit conversion (% BAC / ‰ BAC / mg / L)
3, built-mouthpiece, the mouthpiece can be replaced
4, both sides of the product can be installed in accordance favorite mouthpiece
5, blue backlit digital LCD display
6, lightweight and stylish design, patented products
7, loud alarm sounds
8, the sensor fails, automatic calibration
9, power-saving design, low battery indicator
Battery Installation:
1, marked the battery cover.
2, press the plus or minus grade indicates that the battery is placed 3 AAA (AAA) alkaline batteries.
3, replace the battery cover
Instructions
Preheat
?
1, pressing key 1 second after the "beep" is heard, the tester LCD display will be activated.
2, preheat "Warm up" will appear on the display, after preheating mode, will start countdown from 20-00.
note
Often there will be some gas or debris attached to the tester sensor surface, so when the first time the tester is removed from the package or a long time do not use the tester, you need time to clean and preheat the sensor, if possible, the user We need to press several times as much power key.
test
1, in the warm-up "Warm up" after the success of the blow "Blow" logo will appear on the screen, in the test mode will start counting down from 10-00.
2, buccal mouthpiece to blow normal intensity 3-5 seconds.
3, hear "beep" is heard, the reminder to stop blowing, the test results will be displayed on the screen.
4, when the display shows "Blow 02 or 01", if the user is blowing, LCD digital countdown will jump back to the 03 confirmed
The reaction time is 3 seconds. (Recommended when the countdown began to blow Blow between 09 seconds to 06 seconds, so that the test has enough time to absorb your breath.)
5, automatic sensor calibration: When turned on, the test will check the sensor pattern is normal, if there is any abnormality, can automatically repair (approximately 10 seconds), if not repair, LCD will show "ER". Need on / off about three or more times until you get it to work properly.
reading
1, when the display if it exceeds 0.050% BAC or 0.50 ‰ BAC or 0.25mg / L (BrAC), the tester will sound an alarm.
2, unit conversion: the test result mode, press and hold the "Power" button to transform the unit (% BAC / ‰ BAC / mg / L), the last unit will be displayed as the next test using the unit.
Automatic shut-down
Test results show that about 20 seconds on the LCD, it will be automatically shut down.
?
Replace the mouthpiece
Mouthpiece mouthpiece out from the back of the box products, according to their own preferences mounted on the left or right side of the product.
Replacement battery
LCD screen flashing prompt battery is low, replace the alkaline batteries.
Technical Parameters
Sensor: high-precision semiconductor alcohol sensor
Detection range: 0.000 ~ 0.199% BAC; 0.00 ~ 1.99 ‰ BAC; 0.00 ~ 0.99 mg / L (BrAC)
Alarm points: 0.050% BAC; 0.50 ‰ BAC; 0.25mg / L (BrAC)
Accuracy: ± 0.010% BAC; ± 0.10 ‰ BAC; ± 0.05mg / L
Reaction time: !#!lt!*!5s Warm-up time: !#!lt!*!20s
Operating voltage: 3 AAA alkaline batteries
Current job: ≤120mA
Working environment: -10 ℃ ~ 50 ℃
Display: blue backlight 3-digit LCD display
?
Precautions:
A, at least 20 minutes before drinking the test, because alcohol absorbed into the bloodstream from the digestive system takes about 20 minutes. Drink immediately test results reflect only the alcohol concentration was in the mouth instead of blood alcohol concentration contained.
B, so that the test results are accurate to 20 minutes after drinking, etc. Please re-test, the test of time better than 3 minutes from the last test.
C, do not wipe the product with chemicals or directly dissolving liquid containing corrosive, avoid liquid into the blowing tube.
D, if in environments with high concentrations of gas, the product will not work properly.
E, if the presence of the test, the test value and the real value of the difference between the low battery charge is prohibited placement and use in paints, pesticides, alcohol and other corrosive gases or polluted air enclosed environment.
F, unauthorized repairs and damage the internal parts can cause product failures.
G, after prolonged use, the tester may be dirt, use a clean cloth to wipe.
?
?
postscript
Drink driving and drunken driving standard: driver blood alcohol content greater than or equal to 20mg / 100ml, less than 80mg / 100ml of drink-driving, alcohol content greater than or equal to 80mg / 100ml to drunk driving.
Under normal circumstances, if just drinking the wine and breath test, the display value may be relatively high, but 20 to 30 minutes after the test, the value may decline, but this value is more accurate, because when alcohol It has been absorbed into the bloodstream through digestion. While the traffic police for drunk driving penalties threshold is 20mg (or 0.02g), but this does not mean that less than 20mg (or 0.02g), driving is safe. Whether large or small amount of alcohol drinker, drinking as long, and no matter how much, it is best not to have to drive, which is both responsible for the others, but also to themselves.
In theory, a person drinking 350ml (equivalent to about 1 vial) of beer or wine and a half two (20ml), the blood alcohol concentration can reach 20mg / 100ml; when alcohol consumption rose to 1400ml (equivalent to about 3 bottles of 500ml) a beer or two and a half of liquor (80ml), the blood alcohol concentration up to 80mg / 100ml. This data and the actual test results have some access, the reason is that the body's absorption of alcohol, different decomposition. Also a glass of wine, a drink that could not feel a thing, and another drink, it may be rotten drunk drunk. In addition, the use of the breath tester most accurate results are not necessarily accurate, most accurate way to detect or to test through blood. This is also the reason for the traffic police found blood testing must be carried out when the driver drunk driving lies.
According to the World Health Organization report: When the driver blood alcohol content of 80mg / 100ml, is drunk driving reached a critical value, the chance of traffic accidents is 2.5 times the blood when non-alcoholic. Blood alcohol content of 100mg / 100ml, the chance of accidents is 4.7 times the blood when the non-alcoholic.