| General specifications: | ||||
| Max. V between terminals !#!amp!*! earth: | 1000V DC or 750V rms AC | |||
| Operating temperature: | 0 to 40→ (32 to 104?) | |||
| Storage temperature: | -10 to 50→ (10 to 122?) | |||
| Operating altitude: | Max. 2000 meters (7000 ft.) | |||
| Max. diameter for conductor: | Diameter 26mm | |||
| Max. displayed value: | 4000 digits | |||
| Auto polarity indication: | "-" for negative polarity. | |||
| Over-range indication: | "0L" or "-0L" | |||
| Converter rate: | 3 times/sec; Bar graph: 30 times/sec | |||
| Auto power off time: | 15 minute | |||
| Power supply: | 3 x 1.5V AAA battery (Not included) | |||
| Multimeter size: | 20.8 x 7.8 x 3.5cm / 8.2 x 3.1 x 1.4in | |||
| Multimeter weight: | 238g / 8.4oz | |||
| Package size: | 23 x 10.5 x 6cm / 9.1 x 4.1 x 2.4in | |||
| Package weight: | 469g / 16.5oz | |||
| Measurement specifications accuracy | ||||
| AC Current | 40A/400A | ±2.0% | ||
| DC Current | 40A/400A | ±2.0% | ||
| DC Voltage | 400mV | ±1.0% | ||
| 4V/40V/400V | ±0.7% | |||
| 600V | ±0.8% | |||
| AC Voltage | 4V/40V/400V | ±0.8% | ||
| 600V | ±1.0% | |||
| Frequency | By A range (current clamp) | 10Hz/1kHz/!#!gt!*!1kHz | ±1.5% | |
| By ACV range | 10Hz/1kHz/10kHz | ±1.5% | ||
| !#!gt!*!10kHz | Take it only as reference | |||
| By Hz/DUTY range | 9.999Hz/99.99Hz/999.9Hz/9.999kHz/99.99kHz/ 999.9kHz/9.999MHz | ±0.5% | ||
| Resistance | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ | ±0.8% | ||
| 40MΩ | ±1.2% | |||
| Capacitance | 40nF/400nF/4uF/40uF/400uF/4000uF | ±4.0% | ||