This product includes:
100PCS PCT-102/773-102
100PCS PCT-104/773-104
50PCS PCT-106/773-106
50PCS PCT-108/773-108

PCT-102
Safety information 1 In grounded power lines
Safety information 2 When using conductors of exclusively the same cross section, 0.75 mm²/AWG 18 is also possible.
Rated voltage (II / 2) [V] 400 V
Rated impulse voltage (II / 2) [kV] 4 kV
Rated current [A] 24 A
Total number of potentials 1
Type of wiring Side-entry wiring
Number of connection points (connection type) 2
Actuation type Push-in
Connectable conductor materials Copper
Solid conductor 0.75 … 2.5 mm² / 18 … 12 AWG
Stranded conductor 1.5 … 2.5 mm² / 16 … 12 AWG
Strip length 12 mm / 0.47 Inch
Width 9.2 mm / 0.362 Inch
Height 13.1 mm / 0.516 Inch
Depth 19.5 mm / 0.768 Inch
Total number of connection points 2
Fire load [MJ] 0.036 MJ
RoHS Conformity 1
Weight [g] 1.538 g

PCT-104
Safety information 1 In grounded power lines
Safety information 2 When using conductors of exclusively the same cross section, 0.75 mm²/AWG 18 is also possible
Rated voltage (II / 2) [V] 400 V
Rated impulse voltage (II / 2) [kV] 4 kV
Total number of potentials 1
Type of wiring Side-entry wiring
Number of connection points (connection type) 4
Actuation type Push-in
Connectable conductor materials Copper
Solid conductor 0.75 … 2.5 mm² / 18 … 12 AWG
Stranded conductor 1.5 … 2.5 mm² / 16 … 12 AWG
Strip length 12 mm / 0.47 Inch
Width 13 mm / 0.512 Inch
Height 13.1 mm / 0.516 Inch
Depth 19.5 mm / 0.768 Inch
Total number of connection points 4
Fire load [MJ] 0.055 MJ
RoHS Conformity 1
Weight [g] 2.511 g

PCT-106
Safety information 1: In grounded power lines
Safety information 2: When using conductors of exclusively the same cross section, 0.75 mm²/AWG 18 is also possible.
Rated voltage (II / 2) [V] 400 V
Rated impulse voltage (II / 2) [kV] 4 kV
Rated current [A] 24 A
Total number of potentials 1
Type of wiring Side-entry wiring
Number of connection points (connection type) 6
Actuation type Push-in
Connectable conductor materials Copper
Solid conductor 0.75 … 2.5 mm² / 18 … 12 AWG
Stranded conductor 1.5 … 2.5 mm² / 16 … 12 AWG
Strip length 12 mm / 0.47 Inch
Width 18.8 mm / 0.74 Inch
Height 13.1 mm / 0.516 Inch
Depth 19.5 mm / 0.768 Inch
Total number of connection points 6
Color transparent
Fire load [MJ] 0.075 MJ
Weight [g] 3.55 g

PCT-108
Safety information 1: In grounded power lines
Rated voltage (II / 2) [V] 400 V
Rated impulse voltage (II / 2) [kV] 4 kV
Rated current [A] 24 A
Total number of potentials 1
Type of wiring Side-entry wiring
Number of connection points (connection type) 8
Actuation type Push-in
Connectable conductor materials Copper
Solid conductor 0.75 … 2.5 mm² / 18 … 12 AWG
Stranded conductor 1.5 … 2.5 mm² / 16 … 12 AWG
Strip length 12 mm / 0.47 Inch
Width 24 mm / 0.945 Inch
Height 13.1 mm / 0.516 Inch
Depth 19.5 mm / 0.768 Inch
Total number of connection points 8
Color transparent
Fire load [MJ] 0.099 MJ
Weight [g] 4.605 g