1. Measure real-time voltage of the power supply 160~280V AC;
2. Measure real-time operation power of the appliances (0~3000W);
3. Show the power consumption (0~9999kWh);
4. Calculate the cost of energy according to the pre-set price of energy (0~$9999); price of
    energy can be pre-set to the local price by users;
    Two ways for calculating power consumption and power cost: electricity consumption and
    electricity cost in single operation period and accumulated electricity consumption and
    electricity cost in all operation periods; can be manually cleared to 0.
5. Operation condition monitor: The indicator light will flicker when the real-time ratio of
    operation condition reaches its alarm point.
    Ratio of operation condition is the ratio between accumulated operation time per hour
    (running power is over preset standby power) and 1 hour.
    Alarm point for ratio of operation condition and standby power can be pre-set.
6. Show the operation time of appliances (0~24h~9999d)
    Two ways for calculating operation time: time in single operation period and accumulated
    time in all operation periods; can be manually cleared into 0.
 
 

Parameters:
Voltage: 160~280V AC, 50Hz;
Peak load: 15A
Temperature: -10~60
Humidity: 10~95% RH



Approvals:
CE, RoHS