Kyoritsu 3132A Insulation/Continuity Tester
• | Dust and drip proof construction. (designed to IEC 60529 IP54) |
• | Designed to meet IEC 61010-1 and IEC 61557 safety standard. |
• | 1mA rated test current at the minimum resistance. |
• | 200mA measuring current on continuity testing. |
• | Automatic discharge of circuit capacitance. |
• | Live circuit warning buzzer and neon lamp. |
• | Small and lightweight. Shock resistant new case material. |
• | AC voltmeter with linear, easy-to-read scale. |
• | Operates on AA, R6P×6 dry batteries. |
Insulation Resistance | |
Test Voltage | 250V/500V/1000V |
Measuring Ranges | 100MΩ/200MΩ/400MΩ |
Output Voltage | Rated test voltage+20%, -0% |
Nominal Current | 1mA DC min. |
Output Short | 1~2mA DC |
Accuracy | 0.1~10MΩ/0.2~20MΩ/0.4~40MΩ |
Continuity | |
Measuring Ranges | 3Ω/500Ω |
Output Voltage | 4.1V DC approx. |
Measuring Current | 210mA DC min. |
Accuracy | |±1.5% of scale length |
AC Voltage | |
AC Voltage | 0~600V AC |
Accuracy | |±5% of scale length |
General | |
Safety Standard | IEC 61010-1 CAT.III 600V Pollution Degree 2 |
IP Rating | IEC 60529-IP54 |
EMC Standard | IEC 61326-1 |
Withstand Voltage | 3700V AC for 1 minute |
Power Source | R6P (AA) (1.5V) × 6 |
Dimensions | 106(L) × 160(W) × 72(D)mm |
Weight | 560g approx. |
Accessories | 7122B (Test leads) Pouch for test leads |