Debugging of tattoo machine:

You should reboot the tattoo machine to test its performance after finishing the seven steps above.The optimal working condition means finishing the debugging of the tattoo machine.The voltage is 9-12V during liner and 12-12V during coloring or shading with a professional voltage regulator.

Installation of tattoo machine:

DescriptionThis TJ13-c 8 Wrap Coils Carbon Steel Liner Shader Tattoo Machine Blue is a pro-quality beauty product with everything you▽ll need to tattoo and easy to operate. With this machine you can save hours and use it to print high quality and clear tattoo design, low price. Best for beginner.

FEATURES

Specifications

ConditionNew
Frame MaterialCarbon steel
ConstructionStamping
Recommended UseMulti-Use (Shader & Liner)
Coils2pcs 8 wraps coils; 1.1" (28mm)
Working Voltage3-12V
Starting Voltage3V
Optimum voltage5-8V
Running Speed2500-3000round / min
Capacitor47┢,50V
A-Bar MaterialPure iron
Contact materialPure copper
Front Binder MaterialBrass
Rear Binder MaterialBrass
Spring Thickness0.50mm rear spring & 0.50mm front spring
ColorSky bule and Blue
Size3.38 x 0.94 x 2.91 " / 8.6 x 2.4 x 7.4 cm (L x W x H)
Weight4.80oz/136g

Package Includes

Extra Info

Why the machine cannot start
Malfunction Solution
The spring pole does not touch the contact point of the slanting springLoosen the screw of spring pole; rotate down the spring pole to the contact point, and then rotate it through 180▲-360▲. Tighten the screw to lock the spring pole
The switch is offConnect 220V AC power supply and turn on the switch. The indicator flashes red
Both of Adjustable knob (VOLTAGE) and V meter hand are in "0"Rotate the adjustable knob clockwise slowly. Simultaneously, V meter hand is also moving. V meter hand should stop at 10V-12V
The spring pole touches the contact point of front spring so tightly that the machine cannot start, which maybe even cause short circuit. Turn on the switch, the indicator flashes green (No Voltage)Loosen the screw of spring pole; rotate up the spring pole for readjustment to the contact point, and then 180▲-360▲ rotation. The indicator is green after it is short-circuited. Turn off the switch and then on again, the indicator will be red.
Disconnect the cord from joint position owing to careless jerk during the daily workingCheck the foot switch and the plug
The wires are broken while washing and sterilizing the tattoo machineConfirm the broken wires condition and have them welded
Turn on the switch when short circuit happens, and the indicator turns greenCheck whether the plugs of cord and foot switch are broken or not. The damaged ones could cause short circuit, which should be welded with electric iron.