| Function | Measurement Range | Resolution | Accuracy |
| AC Current | 6A | 0.001A | ±(2.5% + 8) |
| 60A | 0.01A | ||
| 400A | 0.1A | ||
| 400~600A | 0.1A | ±(3% + 10) | |
| Maximum Peak Current | 900A | 0.1A | ±(10% + 10) |
| DC Voltage | 6V | 0.001V | ±(0.5% + 3) |
| 60V | 0.01V | ||
| 600V | 0.1V | ||
| AC Voltage | 6V | 0.001V | ±(0.8% + 5) |
| 60V | 0.01V | ||
| 600V | 0.1V | ||
| Clamp Head Frequency | 60Hz | 0.1Hz | ±(1.0% + 5) |
| 1000Hz | 1Hz | ||
| Pass V position | 60Hz | 0.1Hz | ±(1.0% + 5) |
| 1000Hz | 1Hz | ||
| Resistance | 6kΩ | 0.001kΩ | ±(0.8% + 3) |
| 60kΩ | 0.01kΩ | ||
| 600kΩ | 0.1kΩ | ||
| 6mΩ | 0.001kΩ | ||
| 10mΩ | 0.01kΩ | ||
| Line On-off Test | 1Ω | If the resistance of circuit being measured is less tdan 50W, tden tde beeper in tde meter may sound. |