DC 12V 2.5W Solenoid Air Valve 5port 2position BSP 4V110-06 Pilot-operated Type
Specifications:
Material: Alloy Steel
Color: Like the picture show
Quantity: 1 pc
Size(LxWxH): 9.4cm x 1.8cm x2.6cm \/ 3.7!#!amp!*!quot; x 0.7!#!amp!*!quot; x 1.02!#!amp!*!quot;
Wire length: 33cm \/ 12.99!#!amp!*!quot;
Packing box dimension(LxWxH): 10cm x 5.6cm x 2cm
Model: 4V110-06
Positions: 5 ports\/2 positions
Motion Pattern: Pilot-operated Type
Wiring Form: screw thread type
Voltage: DC 12V
Allowable Voltage Fluctuation: !#!amp!*!plusmn;10% of Rated Voltage
Power Consumption: AC:2.5VA \/ DC2.5W
Operating Tempe: -5 to + 50 C \/ 41-122 F
Effective Section Area: 12mm!#!amp!*!sup2; (CV=0.67)
Port Size: Air Inlet=Air Outlet=Exhaust=1\/8!#!amp!*!quot;BSP
Working Media\/Fluld: 40 Micron Filtered Air
Operating Pressure: 0.15-0.8 MPa \/ 22-116 PSI
Max. Pressure Resistance: 1.2MPa \/ 174 PSI
Insulation and Protection Class: F Class \/ IP65
Highest Action Frequency: 5\/s
Shortest Excitation Time: 0.05 second
Feature:
Pilot-operated Type: external and internal optional
Strut structure, good sealing, responsive
Three-position solenoid valve has three central features to choose from
Double two position solenoid valve with memory function
The hole using a special process, friction resistance, low starting pressure, long life
Can be integrated with the base valve, saving installation space
Has a manual device, installation and commissioning conducive
Trouble Shooting:
1.After energizing the solenoid valve does not work:
Check the power wiring is bad !#!amp!*!rarr; Re-connect wiring and connectors
Check the power supply voltage in the range of !#!amp!*!plusmn; work !#!amp!*!rarr; To adjust the range of the normal position
Coils are sealing off !#!amp!*!rarr; Re-welded\u3000
Coil shorted !#!amp!*!rarr; Replace the coil
Working pressure difference is not appropriate !#!amp!*!rarr; Adjust the pressure differential\/Replace solenoid valve
The fluid temperature is too high !#!amp!*!rarr; Replace solenoid valve
Have impurities to make electromagnetic valve of the main valve core and the moving core card to death !#!amp!*!rarr;
Cleaning,such as sealing damage the seal and install the filter should be changed
Liquid viscosity is too large,the frequency is too high and had come to life !#!amp!*!rarr; Replacement product
2.Solenoid valve can not be closed:
The main valve core or moving iron core of seal is damaged !#!amp!*!rarr; Replace the seal
The fluid temperature, viscosity is too high !#!amp!*!rarr; Replacement of the solenoid valve
Are valve core production impurities into the solenoid valve or moving iron core !#!amp!*!rarr; cleaning
Spring life have to or deformation !#!amp!*!rarr; change
Orifice balance hole plug !#!amp!*!rarr; In a timely manner to clean
Working frequency is too high or have to life !#!amp!*!rarr; Reelection products or product updates
3.Other cases:
Internal leakage !#!amp!*!rarr; Check whether the seal is damaged, the spring is bad assembly
External leakage !#!amp!*!rarr; Joint looseness or seal has been bad !#!amp!*!rarr; Screws or replace t