




Item Descriptions:
Product introduction
It is a thermometer that measures the temperature toward the forehead and the temperature measurement result is projected to the forehead.
It does not touch the skin and it warms up in 1 second in the shortest.
It is recommended for baby 's temperature measurement that is still sensitive to stimulation and does not quite stand still.
"Manual calibration function" adopted so that you can use it in a short time even if you bring it from a cold room.
In the conventional model, it was necessary to wait until it became familiar with room temperature (about 10 to 20 minutes), but if you use the manual configuration function of this item you will be able to use it with button operation of about 10 seconds.
Utility model registration No. 3202139
In addition:
· You can measure not only body temperature but also food temperature and room temperature.
· Thermometry results Up to 9 items can be saved.
· With neck strap.
● Generic name
Skin infrared thermometer
● Contraindication / Prohibition
· Do not drop or bump this product and give a strong shock from the outside.
In particular, do not give shock to the measuring sensor part.
[This will cause the whole function to stop.
· Be sure to refer to the package insert of the medical device to be used in combination.
· When the measurement result exceeds 40.0 ℃, it is set so that error indication appears.
However, since the temperature judged to be exothermic by humans is different, do not judge the presence or absence of heat by only displaying an error.
· Do not use in conditions that do not satisfy the usage conditions indicated in the specifications and usage notes, or do not repair, remodel, readjust, etc.
Manufacturers and distributors are not responsible for the damage caused by these.
● Item specifications
Body temperature measurement range (measurement site: amount): + 34.0 to + 42.5 degrees
Object surface temperature measurement range: +1.0 to +55.0 degrees
Room temperature measurement range: + 5.0 to + 40.0 degrees
+0.0 to +19.9 degrees: ± 1.0 degrees, + 20.0 to +35.9 degrees: ± 0.3 degrees, + 36.0 to +39.0 degrees: ± 0.2 degrees, +39.1 to +0.3 degrees,
+42.5 degrees: ± 0.3 degrees, +42.6 to +55.0 degrees: ± 1.0 degrees
Operating environment Temperature and humidity: +16 to + 40 degrees * 1 15 to 93% RH (with no condensation)
Storage environmental temperature: -10 to +60 degrees (with no condensation)
Mechanical shock: It must not exceed the range of body temperature measurement accuracy.
Influence of long-term stability: Do not exceed the range of body temperature measurement accuracy.
Minimum display unit: 0.1 degree
Electromagnetic compatibility (EMC) complies with EN 60601-1-2: 2007.
* 1: You can operate the [Face] button even in the temperature range of +10.0 to + 15.9 degrees.
You can also operate the [Home] button even in the temperature range of + 5.0 to + 15.9 degrees.
In either case the accuracy is not guaranteed.
At this time, the measured temperature is alternately projected and displayed as "Lo.5" and temperature.
● Usage Notes
1. Important basic attention
(1) Place this product and accessories in a place out of reach of children.
[There is danger of accidental ingestion or injury.
(2) Do not disassemble or remodel this product.
[It causes a breakdown.
(3) Do not give heavy impact to this product.
[It causes a breakdown.
(4) Do not expose this product to direct sunlight.
[It causes a breakdown.
(5) Do not touch the measuring sensor.
[It may cause malfunction or failure.
(6) Do not immerse this product in liquid.
Do not use in places with liquid.
[It causes a breakdown.
(7) Do not push the measuring sensor or projection light strongly, nor thrust with hard objects or sharp objects.
[It causes a breakdown.
(8) Storage Do not store in environments other than environmental temperature.
[It causes a breakdown.
It can not be measured correctly.
(9) Do not use near a portable short-wave (HF) radio.
[It may cause malfunction or failure.
(10) Do not use if there is damage.
[There is a danger of injury.
It can not be measured correctly.
(11) Do not use if the lens has scratches.
[It can not be measured correctly.
(12) Do not bring the lens into contact with the object to be measured.
[If the lens is damaged it may not be able to measure correctly.
(13) In case of smoke, offensive odor or noise, stop using it immediately.
(14) Do not spill water on this product.
[There is a danger of electric shock.
2. Usage notes
(1) Be aware that it is a product to check body temperature, so it is not a substitute for a doctor's diagnosis.
(2) Temperature is measured beforehand such as ear, forehead, and underarm.
[Depending on individual differences, the forehead and underarm temperature may differ by about 1 ° C.
(3) Do not use it only by children.
[There is a danger of injury.
(4) At the time of measurement, move this product to the place to be measured earlier and make it to the surrounding temperature.
[Because measurement error increases.
(5) Do not hold this product for a long time before measurement.
[This product warms up and can not be measured correctly.
(6) In the body temperature measurement mode, it is not used for the forehead part or body part other than the eyelid.
(7) When measuring in excited state, sweating on the measurement site, when the skin is flushed, when the pulse is early, when taking a vasoconstrictor, when there is a skin rash, when collapsing etc.
, It may appear as temperature change in some cases.
[Sometimes it can not be measured correctly.
(8) Do not measure in a well-ventilated place where the body temperature of the measurement site is deprived.
[Sometimes it can not be measured correctly.
(9) Do not measure at a place where hot air directly strikes, such as near a heater.
[Sometimes it can not be measured correctly.
(10) If it is in the following condition, wait until the temperature of the measurement site stabilizes before measuring.
◦ When you are exercising just before.
◦ If you were at a temperature significantly different from the measurement location until just before.
◦ The case where a cold compress or the like was applied to the measurement site until just before.
◦ If you were wearing a hat etc until just before.
◦ If you used bathing, showering, sauna or hair dryer just before.
(11) Measure the sweat and cosmetics of the measurement site after wiping.
(12) Do not measure by touching the measurement site.
[It can not be measured correctly.
(13) Point the measurement sensor vertically to the measurement site at a distance of 5 to 6 cm.
[When it shifts, it can not be measured correctly.
(14) When an error message is projected and displayed, check the item "Troubleshooting" in the instruction manual and take appropriate action.
Information on Manufacturers and Manufacturers (Inquiries on Products)
Manufacture and seller: Custom Co., Ltd.
Phone number: 03-3255-1117
Manufacturer: TECNIMED SRL (Technimed)
Country of import: Italy
● Electrical rating
Power supply: 2 AAA batteries
Power supply voltage: DC 3 V
Maximum power consumption: 1 W
Usage notes
Please refer to the instruction manual always.
Features:
Product information:
Shipping Weight: 149 g
Package Dimensions: 3.61 x 9.70 x 16.00 cm
SHIPPING METHOD
Delivered directly from Japan by Japan Post. It will take 3 to 5 business days to prepare the order for shipping. We guarantee careful packing and safe shipping.Please note that in some cases additional import or VAT charges may incur and have to be borne by the client.
1. Japanpost registered mail
Shipment by Japanpost Registered Mail (Standard). Trackable any time with tracking number. Insurance is not available. Delivery time usually is between 1-3 weeks from the date of dispatch. Some items are not eligible for Standard Shipping.
2. Qxpress Standard
Shipment by Qxpress standard service. Trackable at any time with tracking number. Registered and insured up to a value of item price and shipping fees.Delivery time is usually between 5-10 business days from the date of dispatch.
3. EMS
Shipment by Expedited Mail Service. Trackable at any time with tracking number. Registered and insured up to a value of $200 and usually delivered in 2-6 business day from the date of dispatch.

| Japanpost registered mail | Qexpress | EMS | |
|---|---|---|---|
| Shipping Method | Japanpost Registered Mail (Standard) | Standard Qexpress | EMS (Expedited Mail Service) |
| Trackable | Yes | Yes | Yes |
| Insured | N/A | Yes (Up to item price and shipping fees) | Yes (Up to $200.00) |
| Asia | 1-3 weeks | 5-10 days | 2-5 days |
| Oceania; North America; Central America and the Middle East | 2-4 weeks | 6-14 days | 2-6 days |
| Europe | 2-4 weeks | 6-16 days | 3-8 days |
| South America and Africa | 2-4 weeks | 10-18 days | 4-8 days |
NOTICE:
"According to Qoo10 guide line,overseas shipping fees will be charged to you extra if you choose Qxpress standard shipping.We recommend you to compare the total price of your purchase with EMS."
