MQ-2 gas sensor detects smoke methane butane analog sensor (H1B5)

First・size : 32mm X22mm X27mm length X width X height

Second・the main chip : LM393・ZYMQ-2 gas sensor

Third・the working voltage : DC 5 V

Four characteristics:

1・having a signal output instruction .

2・the dual signal output ( analog output and TTL level output )

3・0 ~ 5V analog output voltage・the higher the concentration・the higher voltage.

4・liquefied petroleum gas・natural gas・city gas・smoke have better sensitivity.

5・with a long life and reliable stability

6・rapid response and recovery characteristics

V. Application :

For home or factory gas leakage monitoring device・suitable for liquefied petroleum gas・butane・propane・methane・alcohol・hydrogen・smoke and other monitoring devices.

MQ-2 gas sensor parameters :

?

?



A. Standard Operating Conditions

?

?Connection mode:
1・VCC: is connected to the positive pole (5V)
2・GND: with the negative electrode of the power
3・the DO:TTL switch signal output
4・AO: output signal

Symbol

Parameter name

Technical conditions

Remark

Vc

Circuit voltage

+15V

AC or DC

VH

Heating voltage

5.0V\0.2 V

AC or DC

RL

Load Resistance

Adjustable

?

RH

Heating resistors

31Ω\3Ω

Room temperature

PH

Heating power

+900mW

?

?

B. Environmental Conditions

?

?

Symbol

Parameter name

Technical conditions

Remark

Tao

Temperature

-10<-50<

?

Tas

Storage temperature

-20<-70<

RH

Relative humidity

Less than 95% RH

O2

Oxygen concentration

21% ( standard conditions )

Oxygen concentration can affect sensitivity

A minimum value greater than 2%

?

C. sensitivity characteristics

?

?

Symbol

Parameter name

Technical parameters

Remark

Rs

Sensitive surface resistivity

3KΩ-30KΩ

(1000ppm isobutane )

Probe concentration range

100ppm-10000ppm

LPG and propane

300ppm-5000ppm Butane

5000ppm-20000ppm methane

300ppm-5000ppm hydrogen

100ppm-2000ppm alcohol

α (3000/1000)

Isobutane

Concentration slope

???????

+0.6

Standard Operating Conditions

Temperature : 20< \2<Vc: 5.0V\0.1V

Relative humidity : 65%\5% Vh: 5.0V\0.1V

Warm-up time

No more than one hour




Packaging Details
Unit Type: lot (10 pieces/lot) Package Weight: 0.600kg (1.32lb.) Package Size: 5cm x 5cm x 5cm (1.97in x 1.97in x 1.97in)


?