1.Placement GuidelineFor optimun operation,the inverter should be placed on a flat surface as the floor or car under these confitions as fallows:
Dry: no water or get wet in the rain Cool: the temperature between 0 ;(32 F)and 40 ;(104 )
Ventilation:at lease 2 inches (5cm) clearance above and on all sides lf the TSM inverter for proper cooling .
2.Usage of the Inverter
a.turn the inverter switch to (OFF) position, and then plug the inverter DC Plug into the car cigarette lighter socket,make sure of they are firmly linked.
b.make sure the electrical power of the Equipments you use is under the electrical power of the TSM inverter.Plug the AC product you wish to operate into the AC 220V outlet of the inverter and switch it on.
c.Switch the inverter on, the green light indicates that it is working normally.
d.The red FAULT light indicates inverter shutdown caused by low or hight voltage,overload or excessive temperature.
e.In many cases,for the limited voltage from the car cigarette lighter,it may shutdown automatically and the Fault Red light will belighted.
3. Warning and Cautiona.
a. The powet or voltage ; rating of AC products is the average power they use. TVs, monitors, electric motors,and other equipments are firstly switch on.They consum more power thantheir power rating,having high surge requirement on starting up.Although RLD inverter can supply momently surgte power as high as 40%more(for example,80w RLD inverter can supply 120W for the products you use).But ,the surge power of the equipments you use may be excess of the power supplied by the inverter,causing overload shutdown.Specially happen when inverter supply power to several products at the same time.Then you should switch off the electrical products,switch on the inverter,lastly switch on one by one, the products that has the peak power firstly.
b. As the battery charge is using up,the inverter sences DC input voltage has dropped to 10.4-11V, an audio warning will appear. Then the computer or other sensitive electrical appliances should be shut down. ifyou ignore the sound,and the voltage drops to 9.7-10.3V, the inverter will automatic turn-off to avoid battery discharge excessively. Power Protection make it shut down, the red indicator light is turned on.
c. Start thr vehicle early for battery charging, to prevent its capacity drpping,to prevernt the impact on vehicle starting and the battary life.
d. Although there isover-voltage protection function ofinverter,it may be damaged by excessive voltage.
e. After continuous use, the shell surface temperaturewill rise to 60 ;,pay attention to keep ventilation,objects that is susceptible to heat should be kept away from it.
4.Frequently Asked Questions and solutions
questions (with solution): do not work, switches light does not shine
The reasons and the proposed solution
(1)Bad battery: check battery, according to the specific circumstances of the replacement
(2)Anti-contact of the outlet : check battery connections, converters may be damaged, or sent to replace the converter warranty.
(3)Untighten junction to the DC input: check wiring cables and links, tightened the terminal contact.
questions(with solution): electrical equipment does not work, the red indicator light converter The reasons and the proposed solution .
(1)AC product power consumption is higher than rated. Solution:Try to use power converters that is less than the nominal electrical power
(2)Electrical power converter is less than nominal power or peak power is too high,will cause overload shutdown.. Solution:try to use the same surge power as the inverter.
(3)The battery is use up(with the inverter warning)
Solution: Recharging or replacement of it .
(4) High temperature caused by poor ventilationmake inverter shutdown
Solution:cool it for 15 minutesand removethe items around the fan and the inverter. Put the inverter in a cool place as required. Restart it.
(5)Input voltage is too high .Solution: check the status of charging system, battery output voltage 12V
problem(with solution): the converter output voltage detected is too low
The reasons and the proposed solutions:
(1) General measurement of the voltage metergivessmall measurement range. Solution: to get the output square-wave converter applications,use the"True RMS multimeter" in order to obtain accurate data
problem(with solution):the warning of the inverter
The reasons and the proposed solution
(1)Low-voltage or over-temperature protection.
Solution: Usethemore coarse wire or cable torecharge the batteryor reduce the length of the cable. And use the inverter under cool condition or improve the ventilation around theinverter,to make the inverter work normally.
problems(with solution): converter only can drive low-power AC product
The reasons and the proposed solution
the voltage attenuation by a short length of wire,solution: the use of bold wire
problems(with solution): battery usage time is too short
The reasons and the proposed solution
Inverter rated load greater than the use of large-capacity battery Solution: Bad battery, replacement the damaged battery.
The battery is not recharged to be full.
Solution: replacement of better smart charger
CATION: a.do not insert any foreign objects into the inverter or vent opening
b.do not connect the inverter to power utility AC distribution wiring.
c.small battery operate products such as the rechargeable shabers,and night lights were not allowed to be plugged into the inverter to recharge.
d.keep the inverter away from the children.
5 Specifications:
Output voltage:110V
Frequency: 50/60 0.2HZ
waveform:pure sine wave
The greatest effect: 95%
Input Voltage :10-16V
Built-in fuse: 10A/20A/30A/35A/40A
output power: 2000W
Warning Electric Shock Hazard Away from children!!