Auto/manual ranges.
True RMS measurement.
550V protection in resistance and capacitance ranges.
Large LCD display,MAX display 6000 counts.
Sample rate: 3 times per second.
Backlight
Data hold
Polarity identification
Low voltage indication
1200A high current measurement, low current measurement
Auto power off
Main measurements: AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Diode and Continuity Testing, Temperature, Frequency and duty cycle.

Specifications:
Frequency: 5/50/500/5k/50k/500k/5M/10M (¡À0.1+3)
Temperature: <400¡æ ¡À(1.0%+5); ¡Ý400¡æ¡À(1.5%+15); <752¨H ¡À(1.0%+5), ¡Ý752¨H¡À(1.5%+15)
Capacitance: 10nF(¡À5.0+20),100nF/1uF/10uF/100uF(¡À2.0%+5),1000uF/10000uF(¡À5.0%+5)
DC volt: 600mV(¡À1.0%+10), 6V/60V/600V/1000V(¡À0.5%+3)
AC volt: 600mV(¡À3.0%+3),6V/60V/600V/750V(¡À1.0%+3)
ACA/DCA:600uA/6000uA(¡À0.8%+10),60A/600A/1200A(¡À2%+30)
Resistance: 600¦¸(¡À0.5%+3),6K/60K/600K/6M(¡À0.5%+2),60M¦¸(¡À1.5%+3)
Duty cycle:1% to 99%(¡À1%)
Measurement mode: Double-integral style A/D transform
Over range indication: OL
Working environment: 0~40¡æ, relative humidity < 80%
Supply power: 3V (1.5V AA batteries * 2 Pcs)(Not included)
Frequency: 1Hz to 10MHz
Temperature: -20¡æ to 1000¡æ(-4¨H to 1832¨H)
Capacitance: 10pF to 6000uF
AC volts: 0.1mV to 750V
DC volts: 0.1mV to 1000V
AC current: 0.1uA to 1200A
DC current: 0.1uA to 1200A
Resistance: 0.1¦¸ to 60M¦¸
Duty cycle:1% to 99%
Product size: approx. 238*90*45mm/9.37*3.54*1.77''
Gross weight: approx. 286g

Note:
Please allow 1-3mm differs due to manual measurement.
Due to the different display and different light, the picture may not reflect the actual color of the item. Thanks for your understanding.

Included:
1 x Multimeter
2 x Test Leads
1 x Temperature Sensor Cable
1 x Storage Bag
1 x User Manual