• This LCD Digital AC/DC clamp multimeter is a portable clamp meter. It is ideally suited for field, laboratory, shop and home applications.

    Features:
    Manual back light LCD screen, the maximum display value is 5999.
    Multi-purpose clamp meter can measure AC/DC voltage, AC current, temperature, frequency, capacitance measurement and the continuty test, resistance and diode.
    With NCV function(Non-contact voltage detection function).
    Low voltage indication and overload protection.
    High resolution and auto range(some current range is manual range).
    Small and portable to carry and use.
    Data hold, auto range and auto power off.

    Note:
    This UA3016C meter can't measure DC current.

    Specifications:
    Brand Name: UYIGAO
    Color: Orange + Red
    Material: ABS
    Technical Index:1. AC CURRENT
    Range Resolution
    Accuracy

    6A
    0.001A

    ±(2.5% + 10)

    60A
    0.01A

    600A
    0.1A

    1000A
    1A

    - maximum/ input current:1000A AC
    - Frequency range:50Hz

    2.Surge Current
    Range Resolution
    Accuracy

    6A
    0.001A
    <60A as referrence
    ±(5% + 60)

    60A
    0.01A

    600A
    1A

    Integral time:100ms;range:20 ~ 600A;Frequency range:40 ~400Hz
    3. DC Voltage
    Range Resolution
    Accuracy

    60mV
    0.01mV

    ±(0.8% + 5)

    600mV
    0.1mV

    6V
    0.001V

    60V
    0.01V

    600V
    0.1V
    ±(1.0% + 5)
    - Input impedance:10MΩ
    -Maximum/ input voltage:600V AC (Effective value)OR 600V DC
    NOTICE:
    In the small voltage range, one has not received the test circuit, the instrument may be beating reading,
    it'snormal, this is due to the high sensitivity of the instrument .
    without detriment to the actual measurement results.
    4. AC Voltage
    Range Resolution
    Accuracy

    6V
    0.001V
    ±(1.0% + 5)

    60V
    0.01V

    600V
    0.1V
    ±(1.2% + 5)
    - Input impedance:10MΩ
    - Maximum/ input voltage:600V AC (Effective value)or 600V DC
    -Frequency range:40 ~ 1000Hz
    NOTICE:
    In the small voltage range, one has not received the test circuit, the instrument may be beating reading,
    it's normal, this is due to the high sensitivity of the instrument .
    without detriment to the actual measurement results.
    5. Frequency
    5.1Through the V file:
    Range Resolution
    Accuracy

    99.99Hz
    0.01Hz

    ±(1.5% + 5)

    999.9Hz
    0.1Hz

    9.999kHz
    0.001kHz


    - Range:10Hz ~ 10kHz
    - Input voltage range:≥2VAC(Effective value)(With the increase of the measured frequency, the input voltage should be increased)
    - Input impedance:10MΩ
    - Maximum/ input voltage:600V AC(Effective value)
    5.2Through A file(From the clamp head):
    - Frequency response:10 ~ 1kHz
    - Input current range:≥20A AC(Effective value)
    - Maximum/ input current:AC 1000A
    - Input voltage range:≥2V(With the increase of the measured frequency, the input voltage should be increased)
    6. Duty Ratio
    Range Resolution
    Accuracy

    0.1 – 99.9%
    0.1%
    ±3.0%

    6.1Through A file(From the clamp head):
    - Frequency response:10 ~ 1kHz
    - Input current range:≥20A AC(Effective value)
    - Maximum/ input current:AC 1000A
    6.2Through the V file:
    - Frequency response:10 ~ 10kHz
    - Input voltage range:≥60mV AC
    - Input impedance:10MΩ
    - Maximum /input voltage:750V AC(Effective value)

    7. Resistance
    Range Resolution
    Accuracy

    600Ω
    0.1Ω

    ±(0.8% + 3)

    6kΩ
    0.001kΩ

    60kΩ
    0.01kΩ

    600kΩ
    0.1kΩ

    6MΩ
    0.001MW
    ±(1.2% + 3)

    60MW
    0.1MΩ

    -Open-circuit voltage:About 0.4V
    - Overload protection:250V DC OR AC(Effective value)
    8. Continuity Test
    Range Resolution
    Function


    0. 1Ω
    If the measured line resistance is less than 50Ω, enclosing the instrument may sound a buzzer

    - Overload protection:250V DC or AC(Effective value)
    9. Capacitance
    Range Resolution
    Accuracy

    9.999nF
    0.001nF


    ±(3.0% + 5)


    99.99nF
    0.01nF

    999.9nF
    0.1nF

    9.999mF
    0.001mF

    99.99mF
    0.01mF

    999.9mF
    0.1mF

    9.999mF
    0.001mF
    ±(5.0% + 5)

    99.99mF
    0.01mF


    - Overload protection:250V DC or AC(Effective value)
    10.Diode Test
    Range Resolution
    Function


    0.001V
    Show the approximate diode forward voltage value

    - positive DC current 1mA
    - Reverse DC voltage 3.0V
    - Overload protection:250V DC or AC(Effective value)
    Power Supply: 3 * AAA 1.5V Batteries (Not included)
    Maximum Display: 5999
    Opening Size of Jaw: 28mm / 1.10in
    Display Size: 35 * 24mm / 1.38 * 0.94in
    Item Size: Approx. 210 * 78 * 35mm / 8.27 * 3.07 * 1.38in (L * W * H)
    Item Weight: Approx. 229.2g / 8.08oz
    Package Size: Approx. 29 * 15 * 4cm / 11.42 * 5.91 * 1.57in (L * W * H)
    Package Weight: Approx. 456g / 16.1oz

    Package List:
    1 * Clamp Meter
    2 * Test Leads
    1 * Temperature Probe(K type thermocouple)
    1 * Shockproof Sheath