How to Choose Your Aircon

Indoor Unit
BTU of the Indoor Unit indicate the coverage of the cooling area.

(9K BTU) - Small Room Space up to Small Master Bedroom for HDB Flat
(12K BTU) - Large Room Space up to Small Living Room for HDB Flat
(18K BTU) - Large Living Room to Mansionette Living Room for HDB Flat

Outdoor Unit
BTU of the Outdoor Unit indicate the speed to cool down the area.

Outdoor unit T3PS21/SIN 21000BTU
Outdoor unit T4PS28/SIN 28000BTU

SYSTEM
The number of SYSTEM indicate the number of separate room area.

System 1 - 1 Room Area

System 2 - 2 Room Area
System 3 - 3 Room Area
System 4 - 4 Room Area


Things you should know on Upgraded Installation.


  1. Insulation: the material used to cover the copper pipe, usually rubber foam, which helps to absorb water droplets formed due to condensation on the copper pipes when the air-conditioner is operating. There are generally 2 types of insulation: Class 0 and Class 1. An inferior quality will result in a higher condensation rate and cause leakages. ⅜ inches is usually recommended for the piping in trunking (plastic casing that encases the copper pipes, PVC drainage pipes and wiring) while ½ inches is preferred for piping that will be hidden by false ceilings or concealed in walls.
  2. Grade (or gauge): thickness of the copper pipe, generally a thicker copper pipe is able to withstand a higher operating pressure. The grade varies from the lowest SWG (standard working gauge) or G25 (0.51mm) to G21 (thickest). For HDB owners, the G23 (0.61mm) is usually recommended. If you have concealed piping, then G22 (0.71mm) is a better option. Another thing you should take note is the bending of the copper piping. To lower the odds of condensation or poor refrigerant flow (which will make the air-conditioner less cold), make sure that the piping is bent with a proper pipe bender (thus ensuring a pipe bent of about 90 degrees).

 

Terms And Conditions

All Indoor Units Comes With 3 Years Warranty.
All Outdoor Units Comes With 10 Years Warranty.
 All Installation Comes with 15 months Warranty.
For Conceal Trunking/Pipping above False Ceiling will be Quoted Onsite.
FREE 1 time general cleaning within 6 months from installation date.
For Standard New Set Up Installation- Class 0 Armaflex 3/8 inch insulation / G23 Copper Pipe / 13mm Drainage Pipe.
For Upgraded New Set Up Installation- Class 0 Armaflex 1/2 inch insulation / G22 Copper Pipe / 16mm Drainage Pipe.
100% Peace of Mind after Purchase- We will provide Free Onsite Viewing and advice you accordingly to your needs.