| Password as Opening Types. |
| Input the new password. Up to 3 to 19 digits can be registered. |
-Setting on Auto mode : Open the battery cover registration button -Setting on Manual mode : Open the battery cover key registration button |
(button "2" - "9" ) |
| -Outdoor double locking system (protection against burglars throgh milk hole) If you set the outdoor double locking system, the door is not opened even though the open/close button is pressed inside. ※ How to set on Press the button "#" of outer body for 5 seconds. -Indoor double locking system If you set the outdoor double locking system, the door is not opened even though the registered acess-code is pressed outside. ※ How to set on : Press the button "open/close"of inner body for 5 seconds. |
| The door is opened automatically in case that the fire sensor i s sensing the temperature(60˚±5) |
| This function is for protecting against burglars, an emergency alarm comes out for a minute if someone tries to open/close the door compulsory from outside. * If you press the access-code or touch key, the alarm will be off. |
| You can open the door with emergency battery when the battery is discharged. Contact any DC 9V alkaline battery to the emergency terminal of outer body, you can use the access-code or touch key. |
![]() |
![]() |
![]() |
![]() |
| Category | Description | |
| Basic | Model | Everplus2 |
| Use of password | 3-19 digits | |
| Number of touch key to be registered | 50ea or less (touch key applied model) | |
| Door thickness | 35 ~ 50 mm | |
| Size | Outdoor body | 64 (W) X 170 (H) X 24.5 (D)mm |
| Indoor body | 90 (W) X 157 (H) X 37 (D)mm | |
| Material | Outdoor body | AL, ZN, PC |
| Indoor body | AL, ZN ABS | |
| Power | Surface treatment | Triple metallic coating treatment |
| Working power | 6V( Alkaline battry1.5V 4pcs,AA Size) | |
| Emergency power (regardless of polarity) |
9V rectangular alkaline battery (separately pulthased) | |
| Symptom | Troubleshooting |
| The password Is not memorized. | |
| The touch key Is not reglstered. | |
| There are 5 times errors of the password. | Wait during the given time and then input the password or the touch key again from first. |
| The door Is not automatically locked. |
|
| WIlen pressing "*" button, the machine does not work. | If the batteries are used up, replace then by new spares. |
| External button tone and the lampdo not work. | If is so, clean contact portions with a dry cloth. |
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
Open the battery cover in the indoor body. |
| 2 | ![]() |
Press Password/Touch Key Input button. |
| 3 | ![]() |
Input the new password Up to 3 to 19 digits can be registered. |
| 4 | ![]() |
Press "*" button to complete the registration. "Ding-dong" soond will occur to inform you of successful input. |
| * To go to the next stage, perform it before the lamp turns off (within 15 seconds). |
![]() |
| * Register the password with the same method as specified above. * When the new password is registered, the existing password is automatically deleted. |
| * Never fail to register and change the password with the door opened. * The password is set to "1234" at the factory. * After installation, necessarily change it before use. |
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
Open the battery cover in the indoor body. |
| 2 | ![]() |
Press Password/Touch Key Input button. |
| 3 | ![]() |
Contact each touch key to be registered to the external input part to the machine. Up to 1 to 50 keys can be registered. |
| 4 | ![]() |
Press "#" button to complete the registration. "Ding-dong" for |
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
Open the battery cover in the indoor body, and press Password / Touch Key Input button one time. |
| 2 | ![]() |
Two times press ·0" button in the password touch board in the |
| 3 | ![]() |
Press "*" button to complete the deletion. |
| * When the card key is deleted. existing registered card keys are completey ldeleted. Then,. newly register touch keys to be used. |
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
Raise the external cover. ("Beep" sound occurs and the digit board lights on.) |
| 2 | ![]() |
Enter the input password. |
| 3 | ![]() |
Down the external cover or press "*" button. and the door will be opened. |
| * In case five times errors of the password. the machine does not work for 1minute. * When the machine has not worked, you should use it in one minute. |
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
Contact the registered touch key to the touch key input part in the outdoor body. "Ding-dong" sound will occur and the door will be opened. |
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
You can easily open with handle operated inside the body under locking condition.(panic function) |
| 1. Auto mode |
| No | Picture | Function Help |
| 1 | ![]() |
Close the door, and it will be automatically locked in one second. |
| 2. Manual mode |
| No | Picture | Function Help |
| 1 | ![]() |
Raise the external cover or press "#" button. |
![]() |
| 1. Auto mode |
| No | Picture | Function Help |
| 1 | ![]() |
Close the door, and it will be automatically locked in one second. |
| 2. Manual mode |
| No | Picture | Function Help |
| 1 | ![]() |
The door is lockoo manually by turning hand-operated locking device. |
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
|
| Indoor Dual Lock Fuction |
| No | Picture | Function Help |
| 1 | ![]() |
When setting the dual lock function(red) in the indoor body with the door closed, the door does not open although the password or touch keys are used from the outdoor. |
| Outdoor Dual Lock Fuction |
| No | Picture | Function Help |
| 1 | ![]() |
|
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
|
| No | Picture | Function Help |
| 1 | ![]() |
When the door is not closed normally, the machine will try to open the door three times and then "Beep" sound will occur to inform you of an error. |
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
When the door is forcedly opened from the outdoor, the emergency alarm sound will occur for 1minute and inform you of the entrance of outsiders. |
| No | Picture | Function Help |
| 1 | ![]() |
Press Internal Password/Touch Key Input button |
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
When the thermal detection sensor detects heat (60℃±5℃)the door will be automatically opened.
|
![]() |
| No | Picture | Function Help | ||
| 1 | ![]() |
If the built-in battery voltage gets downed. the lamp blinks before 7 days and asaved melody rines. You should replace all of them by new spares.
|
| No | Picture | Function Help | ||
| 1 | ![]() |
Open the bettery cover in the indoor body and then replace all of batteries by new spares. The password or touch key registered are not changed in spite of the exchange of batteries.
|
| No | Picture | Function Help | ||
| 1 | ![]() |
When batteries are completely dischargro due to long·time going out or traveling. you can open the door with safety using the emergency power terminal.
|
![]() |
| No | Picture | Function Help |
| 1 | ![]() |
Contact 9V batlery to the emefgeocy power terminal. |
| 2 | ![]() |
Press "*" button and then the password. |
| 3 | ![]() |
press "*" button again, and the door will be opened. |
| * Contact a 9V battery to the emergency power terminal and then contact the touch key to the touch key input part, and the door will be opened. |