Feature:

Suitable for almost all electric under floor heating systems.
Clock controlled program mode. Each day can be split into 24 single hour periods. Each of these periods can be set to operate at either a comfort temperature、 or an energy saving temperature. Both temperatures (Between 5oC & 30oC) are chosen by the user. The thermostat will operate automatically according to the time and temperature that has been set for each period. (The energy saving mode can be set to a temperature low enough that effectively means the heating is turned off)

A typical example of a set program would be:
*Monday *Comfort mode @ 25oC from 6.00a.m to 9.00a.m
* Energy save mode @ 14oC from 9:00a.m to 4:00p.m
* Comfort mode @ 25oC from 4.00p.m to 10.00p.m
* Energy save mode @14oC from 10.00p.m to 6.00 a.m.
7 day timer. Each day of the week can be programmed individually.
Holiday mode - Temperature can be easily switched to a low level or off whilst the room is unoccupied for a long period of time.
The scheduled event program can be easily overridden at any time and the operating temperature can be set to a desired level. The thermostat will then revert back to the pre-set temperature at the next change of mode.
The scheduled event program can be switched off allowing manual operation of the thermostat if desired.
Combination of temperature sensor options - Air sensor / Floor sensor or Air & Floor sensor.
Over heating protection cut out function. (Temperature to be set by user)
Floor sensor with 3m cable included.
Air sensor built into thermostat.
Battery backup to save settings during power failure.
The thermostat will switch a maximum load of 16amps. (Please see advice below)
Blue back lit LCD screen
1 year manufacturer's warranty.
Full operating & installation instructions included.

Notice:
Although the thermostat is rated to 16Amps、 we strongly recommend that you do not load any thermostat to the full extent of its 16A relay contact rating. It is good practice to restrict the load to 2kW~2.4kW (10A~12A). The relay is rated according to the requirements of EN 61810-1:2004 and EN60730-1 which are not representative of 'real life' applications but an arbitrary test method. Critically、 relay contact life is affected by loading and at 10A~12A the contact life is more than double its life at 16A.



Specifications :

Power Supply: 220 Vac≤10%、50/60HZ. (It is also compatible with 110V)
Max Load; 16A
Power Consumption; 2W
Set Temp Range : 5⊂C -30⊂C
Relative Humidity: 95%RH
Control Accuracy: ≤ 0.5⊂C
Work Ambient: -10⊂C -60⊂C
Floor Overheating Protection: 30oC-60 oC
Protective Housing: IP20
Shell: ABS+PC fire retardant
Backlight Type: Green (defaulted)、 white or blue
Working Mode: On/Off、Floating、Modulating or Multi-fuctions
Certification: CE
Sensor: Internal or External
Floor Sensor: Rubber-thermoplastic NTC 10K
Internal Air Sensor: NTC 10K
Usage FCU System、 or AHU System
Programmability: Non-programmable & Programmable(5+1+1days、5+2 days 4 periods)
Mounting: 86* 86mm & European Mounting

Package include

1pc Heating Thermostat.
1pc 3m cable for External Floor sensor.
English User Guide for operating & installation instructions.