■ Simultaneous display of "now" and "usual" blood pressure values "Average value comparison display" (Can be compared immediately after measurement) ■ Easy to understand size 12 mm character display General name: Automatic electronic sphygmomanometer (Classification: 167 )
Product Name: wrist blood pressure monitor EW-BW13
Contraindication / Prohibition:
[Warning] (It is assumed that there is a possibility of death or serious injury.) ● If you have severe blood circulation disorder in the chest, be sure to consult with your doctor before use. There is a possibility that the cause of the poor physical condition. ● It may be impossible to measure those with few blood flow at the measurement site or those with high frequency of arrhythmia. The judgment depends on the doctor. ● Please do not use for children. ● Please do not use for people who can not express their intention by themselves or those who can not operate by themselves. [Contraindication / Prohibition] (It is a precaution to properly use the sphygmomanometer.) ● If you measure yourself, let's take a diagnosis based on the doctor's guidance. Taking the drug also please follow the doctor. Please do not judge self-judgment, treatment of measurement result. ● Do not wind the compression band (cuff) above the untreated hands such as scratches. ● Do not wind the compression band (cuff) on the arm that is undergoing treatment by intravenous injection or transfusion. There is a danger of injury or accident. ● Do not use near inflammable gases such as anesthesia gas in hospital. There is a possibility of ignition ● Please do not use under high concentration oxygen such as inside high pressure oxygen chamber and oxygen tent in hospital. There is a possibility of ignition. ● Do not put the stent indwelling arm in the compression belt.
Item specification etc.:
● Sales name: handwheel sphygmomanometer EW-BW13 ● Rating: DC 3V (AAA alkaline dry battery LR03 × 2) ● Classification: Mechanical equipment 18 Blood Pressure Test or Pulse Wave Inspection Instrument ● General Name: Automatic Electronic Blood Pressure Monitor (JMDN code 16173000) ● Type of medical equipment: managed medical equipment ● Display method: digital display method ● Measurement method: oscillometric method ● Measurement range: pressure 0 to 280 mmHg pulse rate 30 to 160 beats / min ● Accuracy: pressure ± 3 mmHg Within ± 5% of pulse rate ● Operating temperature and humidity: 10 ℃ ~ 40 ℃ 30% ~ 85% RH ● Storage temperature and humidity: -20 ℃ ~ 60 ℃ 10% ~ 95% RH ● measurable wrist circumference: about 12.5 ~ 22.0 cm ● Body size: 6.4 (length) × 8.9 (width) × 3.4 (thickness) cm ● Weight: 115 g (excluding dry cell) ● Electrical shock protection: Internal power supply equipment BF type ● Error in blood pressure measurement by clinical performance test: Method Standard deviation: within 8 mmHg ● Rapid exhaust: Time required for rapid exhaust from 260 mmHg to 15 mmHg: 10 sec or less ● Stability of cuff pressure indication: 10,000 cycles simulated measurement cuff Table of internal pressures Changes in the value: 3mmHg following the specifications Note:
(1) Do not use for purposes other than blood pressure measurement. (2) Do not disassemble, repair, or modify. It may ignite, cause malfunction or accident. Decomposition seal, please do not remove. (3) Do not use this sphygmomanometer together with other medical equipment. There is a danger of an accident. (4) Do not place equipment that generates electromagnetic waves, such as mobile phones, during measurement close to it. There is a possibility that the blood pressure meter malfunction. (5) You may be measured by yourself under the guidance of a doctor. You may be instructed to measure with the same side's hands and posture at the same time every day. For example, at the measurement time, measure in the morning when measuring in the morning immediately after awakening when there is no urge to gauge, or when difficult, measure before you break the body before breakfast. Let's measure properly according to the doctor's instructions. (6) The compression belt (cuff) can be rolled on either side of the left or right hand. However, since blood pressure is said to have a difference of about 10 mmHg on the left and right, please measure with the hands on the same side each time. (7) Precautions at the time of measurement · Measure with a natural posture with reduced feeling. With your palm up, do not move the muscles of the body or arm, lightly extend your fingers and relax. · Do not talk while measuring. · If you touch the pressure gauge body (cuff) during measurement, or when there is body movement, errors may occur and measurement may not be possible. (8) In order to measure the exact value, measure the blood pressure once, rest for 4 to 5 minutes and measure once more. (9) If measurement fails, the remeasurement mark "U12" will be displayed. (10) If you can not measure correctly, or if you want to continue measurement, press the start ▶ end button once, turn off the power, make sure to rest for 4 to 5 minutes, then press start ▶ end button to measure. (11) When "(Battery Mark)" or "U01" appears, or the display disappears during measurement or nothing is displayed, it is time to replace the battery. Always replace two new AAA alkaline batteries of the same manufacturer at the same time. (12) Start ▶ Remove the surface fastener of the compression band (cuff) if there is a case where the air can not be removed even if you push the end button.
Information on Manufacturers and Manufacturers:
● Manufacturing selling agency: Panasonic Corporation ● Address: 1-5-1 Higashi Shinbashi, Minato-ku, Tokyo Panasonic Tokyo Shiodome Building ● Inquiries: Customer consultation center ● Telephone: 0120-878-365 ● Manufacturer: Panasonic Manufacturing ● Panasonic Manufacturing (Beijing) Co., Ltd.) ● Country of manufacture: People's Republic of China Effect / indication:
To measure systolic blood pressure and diastolic blood pressure non-invasively for health management.