2. Used as a battery charger
Without constant current function module can\'t be used to recharge the battery, due to the consumption of the battery and charger of the pressure difference is very big, cause the charging current is too large, causing cell damage, so start to use constant current charging the battery, when charging to a certain degree of automatic switch back to the constant voltage charging.
Method of use:
(1) to determine the battery float charging voltage and charging current; (if 3.7 V / 2200 mah lithium battery parameters, then float charging voltage of 4.2 V, 1 c, maximum charging current is 2200 ma)
(2) the no-load condition, the module of digital table regulating interface display output voltage to adjust the "constant pressure potentiometer" to make the output voltage float charging voltage;
(3) digital table adjustment to display output current interface, direct the output of the sub module (find a thick wire sub output), regulating the constant current potentiometer to digital current value from the list of predetermined charging current value;
(4) charging lamp current default factory charging current of 0.1 times; (the battery in the process of charging electric current is reduced gradually, and gradually by the constant current charging into constant voltage charging, if charging current setting is 1 A, then when the charging current is less than 0.1 A, blue lights, green lights up, when the battery to complete)
(5) connected to the battery and charging.
(steps 1, 2, 3, 4 is: input power, output light don\'t pick up the battery)
3. Used as LED constant current driver module
(1) make sure you need to drive the LED working current and highest working voltage;
(2) under the condition of no-load, digital table adjustment to display output voltage interface, adjust the "constant pressure potentiometer" make the output voltage at the LED working voltage;
(3) digital table adjustment to display output current interface, direct the output of the sub module (find a thick wire sub output), regulating the constant current potentiometer to digital current value from the list of default LED working current;
(4) connected to the LED, commissioning.
(step 1, 2, 3: input power, output light does not meet the LED light)
Matters needing attention
Module of the input fields, and output don\'t together, this will cause bypass module current sampling resistance, so that the module can\'t adjust the size of the output current, load cases easy to burn the module.
Module series with the output current sampling resistance, when load is connected will be 0 ~ 0.2 V voltage drop, as normal.
Have customers reflect the module can not adjust output voltage, when you encounter this problem, please the potentiometer 10 counterclockwise circle above, using the module can be normal to adjust the voltage. Because of the module factory, the default output voltage at 17 v.
More than 3 a, 35 w output, please strengthen the cooling!

Onboard voltage, ampere meter from calibration method:
1. The onboard digital table shows that the output voltage, long press the right button 2 seconds to loosen, voltmeter, and the output voltage indicator light "OUT" synchronous flash, at this time into the output voltage calibration mode; Similarly, when the input voltage IN the voltmeter display, long press the right button 2 seconds to loosen, voltmeter, and the input voltage indicator light "IN" synchronous flash, at this time into the input voltage calibration mode; When voltmeter display output current, long press the right button 2 seconds to loosen, current meter, this time into the output current calibration mode;
2. Touch the right key, higher voltage (current) a unit, a light touch on the left key, voltage (current) reduce a unit; Due to a unit of voltage is less than 0.1 V, so you need to press the 1-5 consecutive can see the voltmeter change 0.1 V, the concrete continuous button several times depends on the current display voltage, current shows that the higher the voltage, the fewer the number of pedestrian.
3. The voltage (current) after the adjustment, long press the right button for 2 seconds after releasing, can exit the calibration model at this time, all the parameters set up automatic electricity saving.
Note: this function is used to display the precision of calibration of voltage, current, not to adjust output voltage, current value. This feature is designed to meet your higher accuracy requirement, calibrated once you just can get accurate values on the whole range, please feel free to use.