This digital oscilloscope probe is professional oscillometer and very practical for testing the electric current and voltage. The oscilloscope can put the invisible to the naked eye the electrical signals into visible image, convenient for people to study the changing process of various electrical phenomena.
?
Features:
100MHz bandwidth.
1GSa/s real time sample rate.
Large (7.0-inch) color display,WVGA(800x480).
Record length up to 40K.
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
USB host and device connectivity, standard.
Multiple automatic measurements.
Four math functions, including FFTs standard.
Provides software for PC real-time analysis.
VGA Optional.

Note:
Hantek DSO5102P Digital Oscilloscope is for 3 years Warranty?
Please read the instruction manual data CD carefully to avoid injury and prevent damage to this product.

Specifications:
Material: ABS
Bandwidth: 70MHz / 100MHz (Optional)
Plug Type: US / EU (Optional)
Oscilloscope Probe Model: PP-80/150/200
Length of the Powerline: Approx. 150cm / 59.1in
Length of the USB Line: Approx. 107cm / 42.1in
Length of the Probe Line: Approx. 130cm / 51.2in
Size of the Oscilloscope Body: Approx. 31.5 * 13 * 15.2cm / 12.4 * 5.1 * 6.0in (L * W * H)
Oscilloscope Weight: 2.00kg/ 4.4lb
Package Size: Approx. 38.5 * 19.5 * 24cm / 15.1 * 7.7 * 9.4in
Package Weight: 2.87kg/ 6.3lb (2867.5g/101.1oz)
Model DSO5102P
Acquisition
SampleRate Real-TimeSample:1GS/s
AcquisitionModes
Normal Normaldataonly
PeakDetect High-frequencyandrandonglithcapture
Average WavefomAverage,selectable4,8,16,32,64,128
Inputs
InputsCoupling AC,DC,GND
InputsImpendance 1M맺±2%>20pF±3pF
ProbeAttenuation 1X,10X
SupportedProbeAttenuationFactor 1X,10X,100X,1000X
MaximumInputVoltage CATIandCATII:300VRMS(10×),InstallationCategory;
CATIII:150VRMS(1×);
InstallationCategoryII:derateat20dB/decadeabove100kHzto13VpeakACat3MHz*andabove.Fornon-sinusoidalwaveforms,peakvaluemustbelessthan450V.Excursionabove300Vshouldbeoflessthan100msduration.RMSsignallevelincludingallDCcomponentsremovedthroughACcouplingmustbelimitedto300V.Ifthesevaluesareexceeded,damagetotheoscilloscopemayoccur.
HorizontalSystem
SampleRateRange 500MS/s--1GS/s
WaveformInterpolation (sinx)/x
RecordLength 40K
SEC/DIVRange 4ns/divto40s/div
SampleRateand
DelayTimeAccuracy
±50ppm(atoverany≥1mstimeinterval)
PositionRange 20ns/divto80us/div;(-8divxs/div)to40ms;
200us/divto40s/div;(-8divxs/div)to400s
DeltaTimeMeasurementAccuracy
(FullBandwidth)
Single-shot,Normalmode:±(1sampleinterval+100ppm×reading+0.6ns);
>16averages:±(1sampleinterval+100ppm×reading+0.4ns);
Sampleinterval=s/div÷200
VerticalSystem
VerticalResolution 8-bitresolution,allchannelsampledsimultaneously
PositionRange 2mV/divto10V/div
Bandwidth 100MHz
RiseTimeatBNC(typical) 3.5ns
AnalogBandwidthinNormalandAveragemodesatBNCorwithprobe,DCCoupled 2mV/divto20mV/div,±400mV;50mV/divto200mV/div,±2V
500mV/divto2V/div,±40V;5V/div,±50V
Math +,-,*,/,FFT
FFT Windows:Hanning,Flatop,Rectamgular,Bartlett,Blackman;
1024samplepoint
BandwidthLimit 20MHz
LowFrequencyResponse(-3db) ≤10HzatBNC
DCGainAccuracy ±3%forNormalorAverageacquisitionmode,5V/divto10mV/div;
±4%forNormalorAverageacquisitionmode,5mV/divto2mV/div
DCMeasurementAccuracy,
AverageAcquisitionMode
Whenverticaldisplacementiszero,andN≥16:±(3%×reading+0.1div+1mV)only10mV/divorgreaterisselected;
Whenverticaldisplacementisnotzero,andN≥16:±[3%×(reading+verticalposition)+1%ofverticalposition+0.2div];Add2mVforsettingsfrom2mV/divto200mV/div;add50mVforsettingsfrom200mV/divto5V/div
VoltsMeasurementRepeatability,
AverageAcquisitionMode
Deltavoltsbetweenanytwoaveragesof≥16waveformsacquiredundersamesetupandambientconditions
TriggerSystem
TriggerTypes Edge,Video,Pulse,Slope,Overtime,Alternative
TriggerSource CH1,CH2,EXT,EXT/5,ACLine
TriggerModes Auto,Normal,Single
CouplingType DC,AC,NoiseReject,HFReject,LFReject
TriggerSensitivity
(EdgeTriggerType)
DC(CH1,CH2):
1divfromDCto10MHz;1.5divfrom10MHzto100MHz;2divfrom100MHztoFull;
DC(EXT):
200mVfromDCto100MHz;350mVfrom100MHzto200MHz;
DC(EXT/5):
1VfromDCto100MHz;1.75Vfrom100MHzto200MHz;
AC:Attenuatessignalsbelow10Hz;
HFReject:Attenuatessignalsabove80kHz
LFReject:SameastheDC-coupledlimitsforfrequenciesabove150kHz;attenuatessignalsbelow150kHz
TriggerLevelRange CH1/CH2:±8divisionsfromcenterofscreen;
EXT:±1.2V;
EXT/5:±6V
TriggerLevelAccuracy(typical)Accuracyisforsignalshavingriseandfalltimes≥20ns CH1/CH2:0.2div×volts/divwithin±4divisionsfromcenterofscreen;
EXT:±(6%ofsetting+40mV);
EXT/5:±(6%ofsetting+200mV);
SetLevelto50%(typical) Operateswithinputsignals≥50Hz
VideoTrigger
VideoTriggerType CH1,CH2:Peak-to-peakamplitudeof2divisions;
EXT:400mV;
EXT/5:2V
SignalFormatsandFieldRates,VideoTriggerType SupportsNTSC,PALandSECAMbroadcastsystemsforanyfieldoranyline
HoldoffRange 100ns~10s
PulseWidthTrigger