Gas: LPG,Methane,Coal gas Detection range: 300 to 10000 PPMM Characteristics of gas: 1000 PPMM isobutane Sensitivity: R in air/Rin typical gas !#!gt!*!=5 Sensitive resistance: 1k ohm to 20k ohm in 2000PPM isobutane Response time: !#!lt!*!=10s Recovery time: !#!lt!*!=30s Heat resistance: 31ohm +/- 3ohm The heating current: !#!lt!*!=180mA The heating voltage: 5.0V +/- 0.2V Heating power: !#!lt!*!=900mW Measure the voltage: !#!lt!*!=24V
Working conditions: Ambient temperature: -20? ~ + 55? Humidity: !#!lt!*!=95%RH Environmental oxygen content: 21%
Storage conditions: Temperature: -20?~ +70? Humidity: !#!lt!*!=70%RH
|