Debugging of tattoo machine:

You should reboot the tattoo machine to test its performance after finishing the seven steps above.The optimal working condition means finishing the debugging of the tattoo machine.The voltage is 9-12V during liner and 12-12V during coloring or shading with a professional voltage regulator.

Installation of tattoo machine:

DescriptionDo you want to be cool with a colorful and unique tattoo? Do you want to use a tattoo to cover a scar from burning, surgical procedures or other incidents that may feel like a blemish on your body? Today we are excited to recommend this tattoo machine to you. Featuring rapid thermal diffusion, it has a steady performance after continuous working. Made of superior material and fine workmanship, it is safe and convenient to use. This small and lightweight device will give you a lot of convenience. This device won▽t let you down!

FEATURES

Specifications

ModelHB-LHJD006F
Frame MaterialAluminium Alloy
ConstructionCasting to shape
Purpose recommendedShader
Coils10 warps coils; 28mm / 1.1"
Working Voltage4-10V
Starting Voltage4V
Optimum voltage5-8V
Running Speed6000 switch / min (Shader)
Capacitor47┢
A-Bar MaterialPure iron
A-Bar Size1.5" x 0.19" / 3.8 x 0.48cm
Contact materialPure copper
Binding Post MaterialSilicon bronze
Spring Thickness0.50mm rear spring & 0.50mm front spring
Weight4.9oz / 139g
Optimum Voltage5.5~8V
Package Size4.13" x 3.54" x 1.26" / 10.5 x 9 x 3.2cm
ColorBlue

Package Includes

Extra Info

Why the machine cannot start
MalfunctionSolution
The elastic rod does not touch the contact point of the inclined spring plateLoosen the screw of elastic rod, rotate down the elastic rod to the contact point, and then regulate the rod to the right position. Finally tighten the screw to lock the elastic rod.
The switch is offConnect it to 220V AC power supply and turn on the switch. The indicator turns red.
Both of adjustable knob (VOLTAGE) and V meter hand are in "0"Rotate the adjustable knob clockwise slowly. Simultaneously, V meter hand is also moving and should stop at 10V-12V.
The elastic rod touches the contact point of front spring so tightly that the machine cannot start and maybe will cause short circuit. Turn on the switch and the indicator turns green (No voltage)Loosen the screw of elastic rod, rotate up the elastic rod and then rotate it down to the contact point, and finally regulate it to the right position. Restart the power, the machine will be ok.
DisconnectionCheck the foot switch and the plug to avoid disconnecting the cord from the joint position caused by careless jerk.
Broken wiresThe wires be susceptible to damage while washing and sterilizing the tattoo machine, so please confirm the wires condition and have the broken ones welded before use.
Problems of plugs and foot switchTurn on the switch and check whether the plugs of cord and foot switch are broken or not, when short circuit happens (green indicator). The damaged ones should be welded with electric welding rod.